Skip to content

DuraVent Storm Collar 6" DuraPlus

$21.00

Notify me when back in stock

DuraVent DuraPlus Features

  • Seals the Top of the Flashing: Wraps the chimney just above the flashing and sheds water off the outside of the pipe. Sealed with a 500°F non-hardening sealant, it is the piece that stops water tracking down the flashing into the roof.
  • Triple-Wall Insulated Construction: Two separate insulating layers, a ceramic blanket plus a ventilated air space, keep the outer wall cool while holding flue gases hot inside. A hotter flue means stronger draft, less creosote and a stove burning closer to its rated efficiency.
  • Rated to 2100°F for Chimney Fires: UL Listed to UL 103 HT under file MH7399. Built for continuous operation at 1000°F, then tested a full hour at 1400°F and through three separate ten-minute chimney fire tests at 2100°F.
  • Only 2" Clearance to Combustibles: Passes through framing, ceiling and roof with just two inches of air space, so it fits standard 16" on-center construction without reframing the opening.
  • Twist-Lock Connection: Sections join with a precision twist-lock, no locking bands or fasteners. The ceramic blanket is held in position rather than loose-filled, eliminating the hot spots and settling common to poured insulation.

DuraPlus Chimney Storm Collar Specifications

Part Number 6DP-SC
Diameter 6"
Function Weather seal above flashing
Sealant 500°F non-hardening required
Construction Triple-wall, all-fuel
Inner Liner .016" 430 stainless steel
Intermediate Liner .018" aluminized steel
Outer Wall .018" galvanized steel
Insulation Ceramic blanket plus ventilated air space
Connection Type Twist-lock
Clearance to Combustibles 2"
Listing UL 103 HT (MH7399), ULC S629
Continuous Flue Temperature 1000°F
Chimney Fire Rating 2100°F
Approved Fuels Wood, oil, coal, gas

DuraVent Chimney Storm Collar Installation Manual

Download the full manufacturer installation instructions before you begin. Installation must follow these instructions and your appliance manual to stay code compliant and keep the warranty valid.

DuraPlus All-Fuel Chimney Installation Instructions (PDF)

DuraPlus Weather Seal FAQ

How much chimney do I need?

Most wood stove manuals require a minimum total height of 12 feet measured from the stove. Four 36" sections gets you there, plus a ceiling support box, flashing, storm collar and cap to finish the run.

Does it need to be swept like masonry?

Yes. Any solid fuel chimney should be inspected and swept at least once a year. The smooth stainless liner sweeps faster and builds less creosote than masonry, but it still needs the annual service.

Is it covered by a warranty?

DuraVent backs DuraPlus with a limited lifetime warranty when installed to their instructions. Keep your receipt and follow the clearance requirements, since improper installation voids coverage.

Will this work with my wood stove?

If your stove has a 6" flue outlet, yes. Wood stove manufacturers call for a chimney listed to UL 103 HT (2100°F), which is exactly what DuraPlus carries. Drolet, for example, specifies a 6" HT type chimney in its manuals without naming a brand.

Can I connect this to another brand of chimney?

No. Class A chimney systems use proprietary locking joints and are listed as complete systems, so DuraPlus will not join to DuraTech, Selkirk or Ventis. Everything from the ceiling support box to the cap must be DuraPlus.

What is the difference between this and black stovepipe?

They are not interchangeable. Black stovepipe is connector pipe for the exposed run from stove to ceiling only and cannot pass through a ceiling, wall or roof. DuraPlus is Class A insulated chimney, which carries the flue through the building and outside.

How close can this be to framing and insulation?

Two inches of clearance to any combustible, the entire length of the run. Where it passes through an attic you also need an attic insulation shield. Never pack insulation against the chimney even though the outer wall runs cool.

Free Shipping To All Lower 48 States Over $199. All Fire Pits, Bowls, and Heating Products Ship Via Freight LTL Curbside. To Read More About Our Shipping Police. Click Here.

With more than 800+ positive reviews about Fire Pit Surplus, we are confident we can provide you with an excellent buying experience. Read more about how we stand out above the rest on our Why Buy From Us page. 

DuraVent DuraPlus Features

  • Seals the Top of the Flashing: Wraps the chimney just above the flashing and sheds water off the outside of the pipe. Sealed with a 500°F non-hardening sealant, it is the piece that stops water tracking down the flashing into the roof.
  • Triple-Wall Insulated Construction: Two separate insulating layers, a ceramic blanket plus a ventilated air space, keep the outer wall cool while holding flue gases hot inside. A hotter flue means stronger draft, less creosote and a stove burning closer to its rated efficiency.
  • Rated to 2100°F for Chimney Fires: UL Listed to UL 103 HT under file MH7399. Built for continuous operation at 1000°F, then tested a full hour at 1400°F and through three separate ten-minute chimney fire tests at 2100°F.
  • Only 2" Clearance to Combustibles: Passes through framing, ceiling and roof with just two inches of air space, so it fits standard 16" on-center construction without reframing the opening.
  • Twist-Lock Connection: Sections join with a precision twist-lock, no locking bands or fasteners. The ceramic blanket is held in position rather than loose-filled, eliminating the hot spots and settling common to poured insulation.

DuraPlus Chimney Storm Collar Specifications

Part Number 6DP-SC
Diameter 6"
Function Weather seal above flashing
Sealant 500°F non-hardening required
Construction Triple-wall, all-fuel
Inner Liner .016" 430 stainless steel
Intermediate Liner .018" aluminized steel
Outer Wall .018" galvanized steel
Insulation Ceramic blanket plus ventilated air space
Connection Type Twist-lock
Clearance to Combustibles 2"
Listing UL 103 HT (MH7399), ULC S629
Continuous Flue Temperature 1000°F
Chimney Fire Rating 2100°F
Approved Fuels Wood, oil, coal, gas

DuraVent Chimney Storm Collar Installation Manual

Download the full manufacturer installation instructions before you begin. Installation must follow these instructions and your appliance manual to stay code compliant and keep the warranty valid.

DuraPlus All-Fuel Chimney Installation Instructions (PDF)

DuraPlus Weather Seal FAQ

How much chimney do I need?

Most wood stove manuals require a minimum total height of 12 feet measured from the stove. Four 36" sections gets you there, plus a ceiling support box, flashing, storm collar and cap to finish the run.

Does it need to be swept like masonry?

Yes. Any solid fuel chimney should be inspected and swept at least once a year. The smooth stainless liner sweeps faster and builds less creosote than masonry, but it still needs the annual service.

Is it covered by a warranty?

DuraVent backs DuraPlus with a limited lifetime warranty when installed to their instructions. Keep your receipt and follow the clearance requirements, since improper installation voids coverage.

Will this work with my wood stove?

If your stove has a 6" flue outlet, yes. Wood stove manufacturers call for a chimney listed to UL 103 HT (2100°F), which is exactly what DuraPlus carries. Drolet, for example, specifies a 6" HT type chimney in its manuals without naming a brand.

Can I connect this to another brand of chimney?

No. Class A chimney systems use proprietary locking joints and are listed as complete systems, so DuraPlus will not join to DuraTech, Selkirk or Ventis. Everything from the ceiling support box to the cap must be DuraPlus.

What is the difference between this and black stovepipe?

They are not interchangeable. Black stovepipe is connector pipe for the exposed run from stove to ceiling only and cannot pass through a ceiling, wall or roof. DuraPlus is Class A insulated chimney, which carries the flue through the building and outside.

How close can this be to framing and insulation?

Two inches of clearance to any combustible, the entire length of the run. Where it passes through an attic you also need an attic insulation shield. Never pack insulation against the chimney even though the outer wall runs cool.

Free Shipping To All Lower 48 States Over $199. All Fire Pits, Bowls, and Heating Products Ship Via Freight LTL Curbside. To Read More About Our Shipping Police. Click Here.

With more than 800+ positive reviews about Fire Pit Surplus, we are confident we can provide you with an excellent buying experience. Read more about how we stand out above the rest on our Why Buy From Us page.