Skip to content

4" PELLET ATTIC INSULATION SHIELD VOP0301

$70.00

Notify me when back in stock

VOP0301 4" Pellet Attic Insulation Shield Features

  • Required Safety Component: Essential protective shield required when pellet vent pipe passes through a ceiling or floor, ensuring safe installation and code compliance.
  • Dual-Material Construction: Features an outer wall made of durable galvalume steel and an inner wall constructed from corrosion-resistant stainless steel for maximum longevity and performance.
  • Revolutionary Gasket System: Advanced sealing technology prevents leaks without requiring silicone application, simplifying installation and ensuring long-term reliability.
  • Smooth-Weld Technology: Virtually invisible seams provide a clean, professional appearance and enhanced structural integrity throughout the venting system.
  • Precision Formed Ends: Expertly crafted end connections deliver superior fit and finish, making installation easier and ensuring proper alignment with other venting components.
  • Complete with Storm Collar: Includes integrated storm collar for weather protection, preventing moisture infiltration at ceiling and floor penetrations.
  • Universal Compliance: Meets and exceeds all major North American safety standards including NFPA 211, CSA B365, UL 641, CAN/ULC S609, and ULC/ORD C441.

VOP0301 4" Pellet Attic Insulation Shield Specs

Product Code VOP0301
Product Type 4" Pellet Attic Insulation Shield / Firestop
Inner Pipe Diameter (A) 6.75 inches
Overall Height (B) 9.25 inches
Shield Diameter (C) 7.75 inches
Inner Wall Material Stainless Steel
Outer Wall Material Galvalume Steel
Storm Collar Included Yes
Application Ceiling and Floor Penetrations
Compatible Pipe Size 4 inch pellet vent systems
Clearance to Combustibles 1 inch minimum
Safety Certifications NFPA 211, CSA B365, UL 641, CAN/ULC S609, ULC/ORD C441
Suitable For Pellet stoves, corn stoves, biofuel appliances
Installation Location Interior ceilings, floors, attic spaces
Mounting Method 4 corner fasteners (8-penny nails or #8 x 1-1/2" wood screws)
Temperature Rating Continuous flue temperatures up to 570°F
Country of Origin North America

VOP0301 4" Pellet Attic Insulation Shield FAQ

Is the VOP0301 firestop required by building codes?

Yes, the VOP0301 attic insulation shield (firestop) is required by code whenever pellet vent pipe passes through a floor or ceiling. This safety component prevents combustible materials from coming into contact with the vent pipe and ensures proper clearances are maintained. It's mandated by NFPA 211 and other building codes for safe pellet stove installations.

What is the difference between a firestop and an attic insulation shield?

While the terms are often used interchangeably, an attic insulation shield specifically protects the pipe when passing through insulated spaces like attics, preventing blown-in or batt insulation from contacting the vent pipe. The VOP0301 serves both functions, providing structural support at floor/ceiling penetrations and protecting against insulation contact.

Can this be installed from above or below the ceiling?

The VOP0301 can be installed from either above or below the floor or ceiling joists, providing installation flexibility. However, when used as an attic insulation shield, it must be installed from the top. Secure it using four 8-penny nails or #8 x 1-1/2 inch wood screws at each corner for proper support.

Does the storm collar need additional sealing?

The included storm collar should be sealed where it meets the vent pipe using a high-temperature sealant or non-hardening waterproof caulk to prevent moisture infiltration. The VOP0301's revolutionary gasket system means the pipe connections themselves don't require silicone, but the storm collar interface benefits from proper sealing.

What size rough opening do I need to cut?

The rough opening should accommodate the 7.75-inch shield diameter of the VOP0301 while maintaining the required 1-inch clearance to combustible materials. Typically, a 9-10 inch square or round opening is appropriate. Always consult local building codes and the appliance manufacturer's specifications for exact requirements.

Is this compatible with all 4-inch pellet vent systems?

The VOP0301 is designed specifically for 4-inch pellet vent pipe systems and is part of the Vortex pellet vent product line. For best results and warranty compliance, use it with matching Vortex system components. While it may work with other brands' 4-inch systems, compatibility should be verified before installation.

How do I maintain proper clearance to combustibles?

Maintain a minimum 1-inch air space clearance between the vent pipe and any combustible materials such as wood framing, insulation, or drywall. Never fill this clearance space with insulation or other materials. The VOP0301 firestop helps maintain this critical safety clearance at floor and ceiling penetrations.

What warranty coverage does the VOP0301 have?

Warranty coverage varies by manufacturer and installation. Professional installation by certified installers is recommended and may be required for full warranty protection. Contact the retailer or manufacturer for specific warranty terms, as coverage can range from several years to limited lifetime depending on the product line and installation conditions.

4" PELLET ATTIC INSULATION SHIELD Manual:

Free Shipping To All Lower 48 States Over $199. All Fire Pits, Bowls, and Heating Products Ship Via Freight LTL Curbside. To Read More About Our Shipping Police. Click Here.

With more than 800+ positive reviews about Fire Pit Surplus, we are confident we can provide you with an excellent buying experience. Read more about how we stand out above the rest on our Why Buy From Us page. 

VOP0301 4" Pellet Attic Insulation Shield Features

  • Required Safety Component: Essential protective shield required when pellet vent pipe passes through a ceiling or floor, ensuring safe installation and code compliance.
  • Dual-Material Construction: Features an outer wall made of durable galvalume steel and an inner wall constructed from corrosion-resistant stainless steel for maximum longevity and performance.
  • Revolutionary Gasket System: Advanced sealing technology prevents leaks without requiring silicone application, simplifying installation and ensuring long-term reliability.
  • Smooth-Weld Technology: Virtually invisible seams provide a clean, professional appearance and enhanced structural integrity throughout the venting system.
  • Precision Formed Ends: Expertly crafted end connections deliver superior fit and finish, making installation easier and ensuring proper alignment with other venting components.
  • Complete with Storm Collar: Includes integrated storm collar for weather protection, preventing moisture infiltration at ceiling and floor penetrations.
  • Universal Compliance: Meets and exceeds all major North American safety standards including NFPA 211, CSA B365, UL 641, CAN/ULC S609, and ULC/ORD C441.

VOP0301 4" Pellet Attic Insulation Shield Specs

Product Code VOP0301
Product Type 4" Pellet Attic Insulation Shield / Firestop
Inner Pipe Diameter (A) 6.75 inches
Overall Height (B) 9.25 inches
Shield Diameter (C) 7.75 inches
Inner Wall Material Stainless Steel
Outer Wall Material Galvalume Steel
Storm Collar Included Yes
Application Ceiling and Floor Penetrations
Compatible Pipe Size 4 inch pellet vent systems
Clearance to Combustibles 1 inch minimum
Safety Certifications NFPA 211, CSA B365, UL 641, CAN/ULC S609, ULC/ORD C441
Suitable For Pellet stoves, corn stoves, biofuel appliances
Installation Location Interior ceilings, floors, attic spaces
Mounting Method 4 corner fasteners (8-penny nails or #8 x 1-1/2" wood screws)
Temperature Rating Continuous flue temperatures up to 570°F
Country of Origin North America

VOP0301 4" Pellet Attic Insulation Shield FAQ

Is the VOP0301 firestop required by building codes?

Yes, the VOP0301 attic insulation shield (firestop) is required by code whenever pellet vent pipe passes through a floor or ceiling. This safety component prevents combustible materials from coming into contact with the vent pipe and ensures proper clearances are maintained. It's mandated by NFPA 211 and other building codes for safe pellet stove installations.

What is the difference between a firestop and an attic insulation shield?

While the terms are often used interchangeably, an attic insulation shield specifically protects the pipe when passing through insulated spaces like attics, preventing blown-in or batt insulation from contacting the vent pipe. The VOP0301 serves both functions, providing structural support at floor/ceiling penetrations and protecting against insulation contact.

Can this be installed from above or below the ceiling?

The VOP0301 can be installed from either above or below the floor or ceiling joists, providing installation flexibility. However, when used as an attic insulation shield, it must be installed from the top. Secure it using four 8-penny nails or #8 x 1-1/2 inch wood screws at each corner for proper support.

Does the storm collar need additional sealing?

The included storm collar should be sealed where it meets the vent pipe using a high-temperature sealant or non-hardening waterproof caulk to prevent moisture infiltration. The VOP0301's revolutionary gasket system means the pipe connections themselves don't require silicone, but the storm collar interface benefits from proper sealing.

What size rough opening do I need to cut?

The rough opening should accommodate the 7.75-inch shield diameter of the VOP0301 while maintaining the required 1-inch clearance to combustible materials. Typically, a 9-10 inch square or round opening is appropriate. Always consult local building codes and the appliance manufacturer's specifications for exact requirements.

Is this compatible with all 4-inch pellet vent systems?

The VOP0301 is designed specifically for 4-inch pellet vent pipe systems and is part of the Vortex pellet vent product line. For best results and warranty compliance, use it with matching Vortex system components. While it may work with other brands' 4-inch systems, compatibility should be verified before installation.

How do I maintain proper clearance to combustibles?

Maintain a minimum 1-inch air space clearance between the vent pipe and any combustible materials such as wood framing, insulation, or drywall. Never fill this clearance space with insulation or other materials. The VOP0301 firestop helps maintain this critical safety clearance at floor and ceiling penetrations.

What warranty coverage does the VOP0301 have?

Warranty coverage varies by manufacturer and installation. Professional installation by certified installers is recommended and may be required for full warranty protection. Contact the retailer or manufacturer for specific warranty terms, as coverage can range from several years to limited lifetime depending on the product line and installation conditions.

4" PELLET ATTIC INSULATION SHIELD Manual:

Free Shipping To All Lower 48 States Over $199. All Fire Pits, Bowls, and Heating Products Ship Via Freight LTL Curbside. To Read More About Our Shipping Police. Click Here.

With more than 800+ positive reviews about Fire Pit Surplus, we are confident we can provide you with an excellent buying experience. Read more about how we stand out above the rest on our Why Buy From Us page.