VOP0260 Pellet Vent Firestop Features
- Code-Mandated Safety Component: Essential fire protection barrier required by building codes whenever pellet vent pipe penetrates floors or ceilings, preventing dangerous contact between combustible building materials and hot vent pipe.
- Premium Dual-Material Construction: Features a robust galvalume steel outer wall combined with a corrosion-resistant stainless steel inner wall, delivering exceptional strength and long-term durability in demanding heating applications.
- Advanced Leak-Free Gasket System: Incorporates a revolutionary gasket design that creates a superior seal without requiring messy silicone sealants, streamlining installation while ensuring consistent airtight performance year after year.
- Professional Finish Technology: Engineered with smooth-weld manufacturing processes that produce virtually invisible seams, delivering a polished, professional appearance that enhances any residential or commercial interior.
- 4-Inch Diameter Compatibility: Specifically designed for 4-inch pellet vent systems, accommodating larger capacity stoves and heating appliances that burn wood pellets, corn, biofuels, and oil-based fuels.
- Multi-Standard Certification: Meets and exceeds all major North American safety standards including NFPA 211, CSA B365, UL 641, CAN/ULC S609, and ULC/ORD C441, ensuring complete regulatory compliance for both U.S. and Canadian installations.
- Versatile Installation Options: Engineered for installation from either above or below the floor joist, providing contractors and installers with maximum flexibility for new construction, renovations, or challenging retrofit situations.
- Top Flange Design: Features secure top flanges that ensure proper fit and alignment with floor/ceiling joists, creating a stable mounting platform that resists movement and maintains clearances throughout the life of the installation.
VOP0260 Pellet Vent Firestop Specs
| Model Number | VOP0260 |
| Product Type | Pellet Vent Firestop / Joist Shield |
| Inner Pipe Diameter | 4 inches |
| Outer Wall Material | Galvalume Steel |
| Inner Wall Material | Stainless Steel |
| Construction Type | Double-wall, air-insulated |
| Installation Method | Above or below joist |
| Fastening Requirements | (4) 8-penny nails or (4) #8 x 1-1/2" wood screws |
| Clearance to Combustibles | 1 inch (air space) |
| Standards Compliance | NFPA 211, CSA B365, UL 641, CAN/ULC S609, ULC/ORD C441 |
| Required Locations | Each floor and ceiling penetration |
| Compatible Fuel Types | Wood pellets, corn, oil, biofuels |
| Maximum Flue Temperature | Up to 570°F continuous operation |
| Finish | Unpainted galvalume |
| Seal Technology | Gasket system (no silicone required) |
| Manufacturing Process | Precision formed with smooth-weld technology |
VOP0260 Pellet Vent Firestop FAQ
What is the difference between the VOP0230 and VOP0260 firestops?
The primary difference is the inner pipe diameter: the VOP0230 is designed for 3-inch pellet vent systems, while the VOP0260 accommodates 4-inch systems. The larger 4-inch firestop is typically used with higher BTU-rated appliances or stoves with greater heating capacity. Both models feature identical construction quality with galvalume steel outer walls, stainless steel inner walls, and the same revolutionary gasket seal system.
Is a firestop required at every floor level in my installation?
Yes, absolutely. Building codes in both the United States and Canada mandate that a firestop must be installed at every location where the pellet vent pipe passes through a floor or ceiling. This is a critical safety requirement to prevent combustible materials from coming into contact with the pipe. Note that firestops are not required when the pipe passes through the roof itself (appropriate flashing is used instead).
Can I install this firestop if I have limited access to the floor joists?
Yes, the VOP0260 is designed for flexible installation and can be mounted from either above or below the floor joist, making it ideal for situations with limited access. This dual-installation capability is especially valuable in retrofit scenarios or when working in tight spaces like finished basements or attics. Simply cut the properly sized hole, position the firestop, and secure it with four fasteners at the corners.
Do I need to apply high-temperature sealant with this firestop?
No, the VOP0260 features an advanced gasket seal system that eliminates the need for silicone or other high-temperature sealants. This revolutionary design not only makes installation cleaner and faster but also ensures a consistent, reliable seal that won't degrade over time. The gasket system provides superior performance without the mess and additional expense of traditional sealants.
Is this firestop compatible with multi-fuel pellet stoves?
Yes, the VOP0260 is engineered for universal compatibility with all 4-inch pellet vent systems and multi-fuel appliances. It safely vents stoves burning wood pellets, corn, cherry pits, switch grass, coffee husks, walnut shells, soybeans, wheat, sunflower hulls, and other approved biofuels, as well as oil-burning appliances. The system is rated for continuous flue gas temperatures up to 570°F, making it suitable for virtually all residential and light commercial heating applications.
What's the difference between a firestop and a roof flashing?
A firestop is used when the pellet vent pipe passes through a floor or ceiling inside the building structure to prevent combustibles from contacting the pipe. Roof flashing, on the other hand, is used where the pipe exits through the roof to create a weatherproof seal and direct water away from the penetration. When installing through an attic, you'll need both a firestop at the ceiling level and an attic insulation shield, plus roof flashing where the pipe exits.
What warranty protection does this firestop carry?
The VOP0260 is covered under the manufacturer's limited lifetime warranty program, which typically provides 100% replacement coverage for 15 years from the original purchase date, then 50% coverage thereafter. Warranty coverage requires professional installation according to manufacturer specifications, compliance with annual maintenance requirements, and burning only approved fuels. Keep your proof of purchase and product registration. Note that labor and installation costs are not included in warranty coverage.
3" PELLET BLACK WALL PASS-THRU Manual:
Free Shipping To All Lower 48 States Over $199. All Fire Pits, Bowls, and Heating Products Ship Via Freight LTL Curbside. To Read More About Our Shipping Police. Click Here.
With more than 800+ positive reviews about Fire Pit Surplus, we are confident we can provide you with an excellent buying experience. Read more about how we stand out above the rest on our Why Buy From Us page.
VOP0260 Pellet Vent Firestop Features
- Code-Mandated Safety Component: Essential fire protection barrier required by building codes whenever pellet vent pipe penetrates floors or ceilings, preventing dangerous contact between combustible building materials and hot vent pipe.
- Premium Dual-Material Construction: Features a robust galvalume steel outer wall combined with a corrosion-resistant stainless steel inner wall, delivering exceptional strength and long-term durability in demanding heating applications.
- Advanced Leak-Free Gasket System: Incorporates a revolutionary gasket design that creates a superior seal without requiring messy silicone sealants, streamlining installation while ensuring consistent airtight performance year after year.
- Professional Finish Technology: Engineered with smooth-weld manufacturing processes that produce virtually invisible seams, delivering a polished, professional appearance that enhances any residential or commercial interior.
- 4-Inch Diameter Compatibility: Specifically designed for 4-inch pellet vent systems, accommodating larger capacity stoves and heating appliances that burn wood pellets, corn, biofuels, and oil-based fuels.
- Multi-Standard Certification: Meets and exceeds all major North American safety standards including NFPA 211, CSA B365, UL 641, CAN/ULC S609, and ULC/ORD C441, ensuring complete regulatory compliance for both U.S. and Canadian installations.
- Versatile Installation Options: Engineered for installation from either above or below the floor joist, providing contractors and installers with maximum flexibility for new construction, renovations, or challenging retrofit situations.
- Top Flange Design: Features secure top flanges that ensure proper fit and alignment with floor/ceiling joists, creating a stable mounting platform that resists movement and maintains clearances throughout the life of the installation.
VOP0260 Pellet Vent Firestop Specs
| Model Number | VOP0260 |
| Product Type | Pellet Vent Firestop / Joist Shield |
| Inner Pipe Diameter | 4 inches |
| Outer Wall Material | Galvalume Steel |
| Inner Wall Material | Stainless Steel |
| Construction Type | Double-wall, air-insulated |
| Installation Method | Above or below joist |
| Fastening Requirements | (4) 8-penny nails or (4) #8 x 1-1/2" wood screws |
| Clearance to Combustibles | 1 inch (air space) |
| Standards Compliance | NFPA 211, CSA B365, UL 641, CAN/ULC S609, ULC/ORD C441 |
| Required Locations | Each floor and ceiling penetration |
| Compatible Fuel Types | Wood pellets, corn, oil, biofuels |
| Maximum Flue Temperature | Up to 570°F continuous operation |
| Finish | Unpainted galvalume |
| Seal Technology | Gasket system (no silicone required) |
| Manufacturing Process | Precision formed with smooth-weld technology |
VOP0260 Pellet Vent Firestop FAQ
What is the difference between the VOP0230 and VOP0260 firestops?
The primary difference is the inner pipe diameter: the VOP0230 is designed for 3-inch pellet vent systems, while the VOP0260 accommodates 4-inch systems. The larger 4-inch firestop is typically used with higher BTU-rated appliances or stoves with greater heating capacity. Both models feature identical construction quality with galvalume steel outer walls, stainless steel inner walls, and the same revolutionary gasket seal system.
Is a firestop required at every floor level in my installation?
Yes, absolutely. Building codes in both the United States and Canada mandate that a firestop must be installed at every location where the pellet vent pipe passes through a floor or ceiling. This is a critical safety requirement to prevent combustible materials from coming into contact with the pipe. Note that firestops are not required when the pipe passes through the roof itself (appropriate flashing is used instead).
Can I install this firestop if I have limited access to the floor joists?
Yes, the VOP0260 is designed for flexible installation and can be mounted from either above or below the floor joist, making it ideal for situations with limited access. This dual-installation capability is especially valuable in retrofit scenarios or when working in tight spaces like finished basements or attics. Simply cut the properly sized hole, position the firestop, and secure it with four fasteners at the corners.
Do I need to apply high-temperature sealant with this firestop?
No, the VOP0260 features an advanced gasket seal system that eliminates the need for silicone or other high-temperature sealants. This revolutionary design not only makes installation cleaner and faster but also ensures a consistent, reliable seal that won't degrade over time. The gasket system provides superior performance without the mess and additional expense of traditional sealants.
Is this firestop compatible with multi-fuel pellet stoves?
Yes, the VOP0260 is engineered for universal compatibility with all 4-inch pellet vent systems and multi-fuel appliances. It safely vents stoves burning wood pellets, corn, cherry pits, switch grass, coffee husks, walnut shells, soybeans, wheat, sunflower hulls, and other approved biofuels, as well as oil-burning appliances. The system is rated for continuous flue gas temperatures up to 570°F, making it suitable for virtually all residential and light commercial heating applications.
What's the difference between a firestop and a roof flashing?
A firestop is used when the pellet vent pipe passes through a floor or ceiling inside the building structure to prevent combustibles from contacting the pipe. Roof flashing, on the other hand, is used where the pipe exits through the roof to create a weatherproof seal and direct water away from the penetration. When installing through an attic, you'll need both a firestop at the ceiling level and an attic insulation shield, plus roof flashing where the pipe exits.
What warranty protection does this firestop carry?
The VOP0260 is covered under the manufacturer's limited lifetime warranty program, which typically provides 100% replacement coverage for 15 years from the original purchase date, then 50% coverage thereafter. Warranty coverage requires professional installation according to manufacturer specifications, compliance with annual maintenance requirements, and burning only approved fuels. Keep your proof of purchase and product registration. Note that labor and installation costs are not included in warranty coverage.
3" PELLET BLACK WALL PASS-THRU Manual:
Free Shipping To All Lower 48 States Over $199. All Fire Pits, Bowls, and Heating Products Ship Via Freight LTL Curbside. To Read More About Our Shipping Police. Click Here.
With more than 800+ positive reviews about Fire Pit Surplus, we are confident we can provide you with an excellent buying experience. Read more about how we stand out above the rest on our Why Buy From Us page.