Skip to content

6" X 18"L VORTEX DOUBLE WALL SLIP SECTION VOD0077

$68.00

Notify me when back in stock

6" X 18"L Vortex Double Wall Slip Section Features

  • Adjustable Length Design: Slides over standard pipe lengths to allow for easy adjustment and connects irregular lengths, providing installation flexibility for custom venting configurations without cutting or crimping.
  • Thermal Weave Technology: The stainless-steel inner wall features an exclusive thermal weave that promotes even airflow and maintains lower outer wall temperatures, enhancing safety and performance.
  • Reduced Clearance Requirements: Double-wall construction allows for just 6 inches clearance to combustible side walls and ceilings, compared to 18 inches required for single-wall pipe, maximizing usable space in your installation area.
  • Premium Metallic Black Finish: Features a durable powder coat finish that provides an attractive aesthetic appearance while resisting corrosion and maintaining its appearance over time.
  • Laser-Welded Construction: Components are assembled using laser welding technology, creating discreet, solid, and durable joints that ensure long-lasting structural integrity and airtight connections.
  • Superior Insulation Value: Double-wall air-insulated design keeps flue gas temperatures higher for enhanced draft performance, reducing moisture, soot, and creosote buildup while improving stove efficiency.
  • High-Quality Materials: Inner wall constructed from 28-gauge 304 stainless steel for maximum corrosion resistance and longevity, with outer wall made of 24-gauge satin coated steel.
  • Universal Compatibility: Designed for use with Vortex Double Wall connector pipe systems, connecting solid fuel-fired appliances including wood stoves, fireplaces, furnaces, and boilers to factory-built chimneys.
  • High Temperature Performance: Engineered to operate at maximum continuous temperatures up to 1,200°F (650°C), handling the demanding conditions of wood-burning appliances.
  • Multi-Standard Compliance: Tested and listed to meet NFPA 211, CSA B365, UL 103 HT, and ULC S629 standards, ensuring code compliance for both USA and Canadian installations.
  • Easy Installation System: Features easy-to-connect parts that simplify installation with self-tapping screws, eliminating the need for specialized tools or complex assembly procedures.
  • Professional-Grade Performance: Suitable for residential wood-burning applications, providing the reliability and safety required for certified wood stoves, fireplaces, furnaces, and boilers.

6" X 18"L Vortex Double Wall Slip Section Specs

Model Number VOD0077
Product Type Double Wall Slip Section
Nominal Diameter 6 inches
Length (YY) 18 inches
Inner Diameter (AØ) 5.9 inches
Outer Diameter at Base (BØ) 7.2 inches
Outer Diameter at Top (CØ) 7 inches
Inner Wall Material 28-gauge 304 stainless steel
Outer Wall Material 24-gauge satin coated steel
Finish Metallic black powder coat
Construction Method Laser welding
Wall Design Double wall with thermal weave
Clearance to Combustible Walls 6 inches minimum
Clearance to Combustible Ceilings 6 inches minimum (5 inches with no adjustable length)
Maximum Operating Temperature 1,200°F (650°C) continuous
Application Solid fuel-burning appliances (wood stoves, fireplaces, furnaces, boilers)
Installation Type Interior connector pipe to factory-built chimney
Connection Method #8 x 1/2" self-tapping screws (minimum 3 per joint)
Adjustability Slides over standard pipe for length adjustment
Standards Compliance NFPA 211, CSA B365, UL 103 HT, ULC S629
Use Case Connecting irregular lengths, custom installations
Warranty Limited lifetime warranty for residential installations
Recommended Maximum Length 15 feet with offset, 20 feet without offset
Country of Manufacture Canada
Installation Environment Indoor residential wood-burning applications

6" X 18"L Vortex Double Wall Slip Section FAQ

What is the purpose of a slip section in a double wall stove pipe system?

A slip section is designed to slide over standard pipe lengths to allow for easy adjustment during installation. The VOD0077 slip section is specifically engineered to connect irregular lengths between your wood stove and chimney, providing flexibility when exact measurements don't align with standard fixed-length pipes. This eliminates the need for cutting pipe sections, which would compromise the double-wall integrity and void warranty coverage. The 18-inch length provides substantial adjustment range while maintaining proper clearances and safety standards.

What clearances are required from combustible materials for this pipe?

The Vortex double wall slip section requires a minimum clearance of 6 inches to combustible side walls and combustible ceilings. This is a significant advantage over single-wall stove pipe, which requires 18 inches of clearance. If your assembled pipe section has no adjustable length sections, clearances may be reduced to 5 inches to combustible side walls and ceilings. These reduced clearances allow you to position your wood stove closer to walls, maximizing usable floor space while maintaining safety compliance with NFPA 211 standards.

Can I use this slip section with other manufacturers' double wall pipe systems?

No, you should only use Vortex Double Wall connector pipe and listed components together. The manufacturer explicitly warns against mixing products from different manufacturers, as this can compromise safety, void your warranty, and violate building codes. Each pipe system is tested and certified as a complete unit, and mixing components may result in improper fit, inadequate clearances, or failure during operation. Always purchase matching Vortex components to ensure proper installation and maintain compliance with UL 103 HT and ULC S629 standards.

How do I properly install and secure this slip section?

The slip section should be connected to adjacent pipe sections using a minimum of three #8 x 1/2" self-tapping screws at each joint. Before securing, slide the slip section over standard pipe lengths to achieve your desired total length. Ensure all sections are properly aligned and fully engaged before drilling and installing screws. For horizontal runs exceeding 4 feet, you must use pipe hangers for additional support, with an additional hanger for every 4 feet thereafter. All connections should be solid and secure to prevent separation during thermal expansion and operation.

What maintenance is required to keep my warranty valid?

To maintain your limited lifetime warranty coverage for residential installations, the double wall connector pipe system must be cleaned and inspected annually by a qualified chimney professional at intervals of no more than 12 months, starting from the date of purchase. Regular cleaning removes creosote, soot, and ash deposits that can accelerate corrosion and reduce efficiency. The warranty covers replacement of defective components when the pipe is used with a residential wood appliance certified by an accredited laboratory and operated within the maximum continuous temperature of 1,200°F. Chemical cleaners should never be used as they can be highly corrosive.

What is the maximum total length allowed for a complete pipe run?

While there is no absolute limitation to the total length of Vortex Double Wall connector pipe (except as stipulated in NFPA 211 or CSA B365), the manufacturer recommends a maximum of 15 feet if there is an offset in your installation. Without an offset, do not exceed 20 feet of total connector pipe length. Longer runs can result in poor draft, excessive creosote buildup, and reduced appliance efficiency. The assembly should be as short and direct as possible between your stove and chimney. Using two 45-degree elbows is often preferable to a single 90-degree elbow to maintain better draft performance.

How does the thermal weave technology benefit my installation?

The exclusive thermal weave featured in the stainless-steel inner wall promotes even airflow between the inner and outer pipe walls while maintaining lower outer wall temperatures. This air-insulated design keeps flue gas temperatures higher, which enhances draft performance, reduces smoking at startup, and minimizes the formation of creosote, soot, and moisture buildup. The cooler outer wall temperatures allow for reduced clearances to combustibles (6 inches versus 18 inches for single wall), making installation safer and more space-efficient. The stainless steel inner wall also heats up faster and stays hot longer than other materials, improving overall system efficiency.

What should I do if a chimney fire occurs?

If a flue fire occurs, immediately close all appliance draft openings and call your local Fire Department. Do not attempt to use the appliance again until the chimney, connector pipe, and stove have been thoroughly inspected by a professional chimney sweep and/or Fire Department Inspector. Chimney fires can reach extremely high temperatures that may damage pipe components, weaken joints, or compromise the structural integrity of your venting system. After inspection, any damaged components must be replaced before resuming use. Regular annual cleaning and inspection significantly reduces the risk of chimney fires by removing combustible creosote deposits.

6" X 6"L VORTEX DOUBLE WALL SLIP SECTION Manual

Free Shipping To All Lower 48 States Over $199. All Fire Pits, Bowls, and Heating Products Ship Via Freight LTL Curbside. To Read More About Our Shipping Police. Click Here.

With more than 800+ positive reviews about Fire Pit Surplus, we are confident we can provide you with an excellent buying experience. Read more about how we stand out above the rest on our Why Buy From Us page. 

6" X 18"L Vortex Double Wall Slip Section Features

  • Adjustable Length Design: Slides over standard pipe lengths to allow for easy adjustment and connects irregular lengths, providing installation flexibility for custom venting configurations without cutting or crimping.
  • Thermal Weave Technology: The stainless-steel inner wall features an exclusive thermal weave that promotes even airflow and maintains lower outer wall temperatures, enhancing safety and performance.
  • Reduced Clearance Requirements: Double-wall construction allows for just 6 inches clearance to combustible side walls and ceilings, compared to 18 inches required for single-wall pipe, maximizing usable space in your installation area.
  • Premium Metallic Black Finish: Features a durable powder coat finish that provides an attractive aesthetic appearance while resisting corrosion and maintaining its appearance over time.
  • Laser-Welded Construction: Components are assembled using laser welding technology, creating discreet, solid, and durable joints that ensure long-lasting structural integrity and airtight connections.
  • Superior Insulation Value: Double-wall air-insulated design keeps flue gas temperatures higher for enhanced draft performance, reducing moisture, soot, and creosote buildup while improving stove efficiency.
  • High-Quality Materials: Inner wall constructed from 28-gauge 304 stainless steel for maximum corrosion resistance and longevity, with outer wall made of 24-gauge satin coated steel.
  • Universal Compatibility: Designed for use with Vortex Double Wall connector pipe systems, connecting solid fuel-fired appliances including wood stoves, fireplaces, furnaces, and boilers to factory-built chimneys.
  • High Temperature Performance: Engineered to operate at maximum continuous temperatures up to 1,200°F (650°C), handling the demanding conditions of wood-burning appliances.
  • Multi-Standard Compliance: Tested and listed to meet NFPA 211, CSA B365, UL 103 HT, and ULC S629 standards, ensuring code compliance for both USA and Canadian installations.
  • Easy Installation System: Features easy-to-connect parts that simplify installation with self-tapping screws, eliminating the need for specialized tools or complex assembly procedures.
  • Professional-Grade Performance: Suitable for residential wood-burning applications, providing the reliability and safety required for certified wood stoves, fireplaces, furnaces, and boilers.

6" X 18"L Vortex Double Wall Slip Section Specs

Model Number VOD0077
Product Type Double Wall Slip Section
Nominal Diameter 6 inches
Length (YY) 18 inches
Inner Diameter (AØ) 5.9 inches
Outer Diameter at Base (BØ) 7.2 inches
Outer Diameter at Top (CØ) 7 inches
Inner Wall Material 28-gauge 304 stainless steel
Outer Wall Material 24-gauge satin coated steel
Finish Metallic black powder coat
Construction Method Laser welding
Wall Design Double wall with thermal weave
Clearance to Combustible Walls 6 inches minimum
Clearance to Combustible Ceilings 6 inches minimum (5 inches with no adjustable length)
Maximum Operating Temperature 1,200°F (650°C) continuous
Application Solid fuel-burning appliances (wood stoves, fireplaces, furnaces, boilers)
Installation Type Interior connector pipe to factory-built chimney
Connection Method #8 x 1/2" self-tapping screws (minimum 3 per joint)
Adjustability Slides over standard pipe for length adjustment
Standards Compliance NFPA 211, CSA B365, UL 103 HT, ULC S629
Use Case Connecting irregular lengths, custom installations
Warranty Limited lifetime warranty for residential installations
Recommended Maximum Length 15 feet with offset, 20 feet without offset
Country of Manufacture Canada
Installation Environment Indoor residential wood-burning applications

6" X 18"L Vortex Double Wall Slip Section FAQ

What is the purpose of a slip section in a double wall stove pipe system?

A slip section is designed to slide over standard pipe lengths to allow for easy adjustment during installation. The VOD0077 slip section is specifically engineered to connect irregular lengths between your wood stove and chimney, providing flexibility when exact measurements don't align with standard fixed-length pipes. This eliminates the need for cutting pipe sections, which would compromise the double-wall integrity and void warranty coverage. The 18-inch length provides substantial adjustment range while maintaining proper clearances and safety standards.

What clearances are required from combustible materials for this pipe?

The Vortex double wall slip section requires a minimum clearance of 6 inches to combustible side walls and combustible ceilings. This is a significant advantage over single-wall stove pipe, which requires 18 inches of clearance. If your assembled pipe section has no adjustable length sections, clearances may be reduced to 5 inches to combustible side walls and ceilings. These reduced clearances allow you to position your wood stove closer to walls, maximizing usable floor space while maintaining safety compliance with NFPA 211 standards.

Can I use this slip section with other manufacturers' double wall pipe systems?

No, you should only use Vortex Double Wall connector pipe and listed components together. The manufacturer explicitly warns against mixing products from different manufacturers, as this can compromise safety, void your warranty, and violate building codes. Each pipe system is tested and certified as a complete unit, and mixing components may result in improper fit, inadequate clearances, or failure during operation. Always purchase matching Vortex components to ensure proper installation and maintain compliance with UL 103 HT and ULC S629 standards.

How do I properly install and secure this slip section?

The slip section should be connected to adjacent pipe sections using a minimum of three #8 x 1/2" self-tapping screws at each joint. Before securing, slide the slip section over standard pipe lengths to achieve your desired total length. Ensure all sections are properly aligned and fully engaged before drilling and installing screws. For horizontal runs exceeding 4 feet, you must use pipe hangers for additional support, with an additional hanger for every 4 feet thereafter. All connections should be solid and secure to prevent separation during thermal expansion and operation.

What maintenance is required to keep my warranty valid?

To maintain your limited lifetime warranty coverage for residential installations, the double wall connector pipe system must be cleaned and inspected annually by a qualified chimney professional at intervals of no more than 12 months, starting from the date of purchase. Regular cleaning removes creosote, soot, and ash deposits that can accelerate corrosion and reduce efficiency. The warranty covers replacement of defective components when the pipe is used with a residential wood appliance certified by an accredited laboratory and operated within the maximum continuous temperature of 1,200°F. Chemical cleaners should never be used as they can be highly corrosive.

What is the maximum total length allowed for a complete pipe run?

While there is no absolute limitation to the total length of Vortex Double Wall connector pipe (except as stipulated in NFPA 211 or CSA B365), the manufacturer recommends a maximum of 15 feet if there is an offset in your installation. Without an offset, do not exceed 20 feet of total connector pipe length. Longer runs can result in poor draft, excessive creosote buildup, and reduced appliance efficiency. The assembly should be as short and direct as possible between your stove and chimney. Using two 45-degree elbows is often preferable to a single 90-degree elbow to maintain better draft performance.

How does the thermal weave technology benefit my installation?

The exclusive thermal weave featured in the stainless-steel inner wall promotes even airflow between the inner and outer pipe walls while maintaining lower outer wall temperatures. This air-insulated design keeps flue gas temperatures higher, which enhances draft performance, reduces smoking at startup, and minimizes the formation of creosote, soot, and moisture buildup. The cooler outer wall temperatures allow for reduced clearances to combustibles (6 inches versus 18 inches for single wall), making installation safer and more space-efficient. The stainless steel inner wall also heats up faster and stays hot longer than other materials, improving overall system efficiency.

What should I do if a chimney fire occurs?

If a flue fire occurs, immediately close all appliance draft openings and call your local Fire Department. Do not attempt to use the appliance again until the chimney, connector pipe, and stove have been thoroughly inspected by a professional chimney sweep and/or Fire Department Inspector. Chimney fires can reach extremely high temperatures that may damage pipe components, weaken joints, or compromise the structural integrity of your venting system. After inspection, any damaged components must be replaced before resuming use. Regular annual cleaning and inspection significantly reduces the risk of chimney fires by removing combustible creosote deposits.

6" X 6"L VORTEX DOUBLE WALL SLIP SECTION Manual

Free Shipping To All Lower 48 States Over $199. All Fire Pits, Bowls, and Heating Products Ship Via Freight LTL Curbside. To Read More About Our Shipping Police. Click Here.

With more than 800+ positive reviews about Fire Pit Surplus, we are confident we can provide you with an excellent buying experience. Read more about how we stand out above the rest on our Why Buy From Us page.