{"product_id":"duravent-chimney-adapter-6dvl-adt","title":"DuraVent Chimney Adapter 6\" DVL to Class A","description":"\u003cdiv class=\"pc-parent-section-container\"\u003e\n    \u003cdiv class=\"pc-ai-features-and-specs-section undefined\"\u003e\n      \u003cdiv class=\"pc-content-flow\"\u003e\n        \u003cdiv class=\"pc-ai-text-container pc-content-flow-mini null\"\u003e\u003ch2\u003eDuraVent DVL Features\u003c\/h2\u003e\u003c\/div\u003e\n        \u003cdiv class=\"pc-ai-text-container pc-content-flow-mini null\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eJoins Stovepipe to Class A Chimney\u003c\/strong\u003e: This is the piece that connects your connector pipe to the Class A chimney at the ceiling support box or wall thimble. Works with both DVL double wall and DuraBlack single wall, and fits DuraPlus, DuraTech and DuraLiner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6\" Clearance Instead of 18\"\u003c\/strong\u003e: The double-wall air-insulated design cuts required clearance to combustibles from 18\" down to 6\", the closest wall clearance of any connector pipe. That is what makes a stove fit in a corner or a tight alcove.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless Steel Inner Wall\u003c\/strong\u003e: A .016\" stainless inner wall heats fast and holds heat longer, keeping the draft strong and steady from the first match. A hotter connector means less condensing flue gas and noticeably less creosote through the season.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBlack Painted Galvanized Outer\u003c\/strong\u003e: The .018\" galvanized outer wall carries a black painted finish with clean welded seams, so the exposed run from stove to ceiling looks finished rather than utilitarian.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Cutting or Crimping\u003c\/strong\u003e: Adjustable and telescoping lengths absorb the odd measurement, so the run is sized on site without a tin snip. Faster installs and no raw cut edge to rust.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n      \u003c\/div\u003e\n      \u003cdiv class=\"pc-content-flow\"\u003e\n        \u003cdiv class=\"pc-ai-text-container pc-content-flow-mini null\"\u003e\u003ch3\u003eDVL Chimney Adapter Specifications\u003c\/h3\u003e\u003c\/div\u003e\n        \u003cdiv class=\"pc-ai-table-container null\"\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e6DVL-ADT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInner Diameter\u003c\/td\u003e\n\u003ctd\u003e6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnects\u003c\/td\u003e\n\u003ctd\u003eDVL or DuraBlack to Class A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible\u003c\/td\u003e\n\u003ctd\u003eDuraPlus, DuraTech, DuraLiner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eDouble-wall, air-insulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInner Wall\u003c\/td\u003e\n\u003ctd\u003e.016\" stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Wall\u003c\/td\u003e\n\u003ctd\u003e.018\" galvanized steel, black painted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearance to Combustibles\u003c\/td\u003e\n\u003ctd\u003e6\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListing\u003c\/td\u003e\n\u003ctd\u003ec-UL-us to ULC S641 (MH14089)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish\u003c\/td\u003e\n\u003ctd\u003eBlack painted, welded seams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eInterior connector pipe, stove to chimney\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnects To\u003c\/td\u003e\n\u003ctd\u003eClass A chimney via 6DVL-ADT adaptor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"pc-ai-text-container pc-content-flow-mini null\"\u003e\u003ch3\u003eDuraVent DVL Pipe Installation Manual\u003c\/h3\u003e\u003c\/div\u003e\n\u003cdiv class=\"pc-ai-text-container pc-content-flow-mini null\"\u003e\n\u003cp\u003eDownload the full manufacturer installation instructions before you begin. Installation must follow these instructions and your appliance manual to stay code compliant and keep the warranty valid.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/duravent.com\/instructions\/L114_820003145_Install_Instructions_DVL_Double-Wall_02-29-24_V4.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDuraVent DVL Double-Wall Installation Instructions (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\u003cdiv class=\"pc-ai-accordian-section pc-ai-faq-section-mini-container pc-content-flow-mini\"\u003e\n      \u003cdiv class=\"pc-ai-text-container pc-content-flow-mini null\"\u003e\u003ch3\u003eDVL to Class A Adaptor FAQ\u003c\/h3\u003e\u003c\/div\u003e\n      \u003cdiv class=\"pc-ai-details-summary-container\"\u003e\n\u003cdetails\u003e\u003csummary\u003eWill it match my stove's finish?\u003c\/summary\u003e\u003cp\u003eIt is a black painted finish with smooth welded seams, which matches the great majority of black wood stoves. Touch-up is standard Stove Bright high-temperature black paint.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eWhat is the difference between DVL and single wall DuraBlack?\u003c\/summary\u003e\u003cp\u003eClearance and price. DVL needs only 6\" to a combustible wall where single wall needs 18\", and its stainless inner wall drafts better and builds less creosote. DuraBlack costs less and is the economical choice when you have the room.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eCan this pass through a wall or ceiling?\u003c\/summary\u003e\u003cp\u003eNo. Connector pipe of any kind stops at the ceiling or wall. To pass through the building you need Class A chimney, and the two join with a chimney adaptor at the ceiling support box or wall thimble.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eHow do I connect this to my stove?\u003c\/summary\u003e\u003cp\u003eUse the DVL stove adaptor (6DVL-AD), which fits the stove's flue collar and gives the pipe a proper mechanical connection. For a rear-exit stove use the tee with cover (6DVL-T) instead.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eHow much connector pipe can I run?\u003c\/summary\u003e\u003cp\u003eMost stove manuals cap the total connector run at 8 to 10 feet with no more than two 90 degree elbows, and any horizontal section must rise at least 1\/4\" per foot toward the chimney.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eDo I need to cut it to length?\u003c\/summary\u003e\u003cp\u003eUsually not. Between fixed 24\" and 48\" lengths and the telescoping section that spans 40\" to 68\", most runs are made up without cutting.\u003c\/p\u003e\u003c\/details\u003e\n\u003cdetails\u003e\u003csummary\u003eCan I mix DVL with single wall pipe in the same run?\u003c\/summary\u003e\u003cp\u003eBetter not to. Clearance is governed by the least protective pipe in the run, so a single wall section forces the whole run back to 18\". Pick one and stay with it.\u003c\/p\u003e\u003c\/details\u003e\n\u003c\/div\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e","brand":"DuraVent","offers":[{"title":"Default Title","offer_id":52557940621543,"sku":"6DVL-ADT","price":81.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0326\/3129\/2039\/files\/6-dvl-durablack-chimney-adaptor-with-trim-6dvl-adt.jpg?v=1788380659","url":"https:\/\/www.firepitsurplus.com\/products\/duravent-chimney-adapter-6dvl-adt","provider":"Fire Pit Surplus","version":"1.0","type":"link"}